Planning check

Estimate warehouse capacity

How many storage locations and how much floor area does your warehouse need, and which storage technology fits? A first range in three minutes, based on the experience values of Bross Consulting.

In brief

The warehouse capacity check turns SKU count, load carrier, inventory and growth into the required storage locations and gross floor area as a range and names the storage technologies that fit this order of magnitude. The values are experience values of Bross Consulting from planning projects; all assumptions are shown.

Your inputs

Required fields are marked with *. Your inputs stay in your browser and are not transmitted.

Assumptions

The check calculates with these experience values. Ranges are shown as from–to; you can change the defaults in the form.

ValueFigureUnitAs of
Design fill level of storage locations85–90%17 November 2026
Growth per year, default3% p.a.17 November 2026
Planning horizon, default5years17 November 2026
Gross area per pallet location, block stacking0.6–1.2m²/location17 November 2026
Gross area per pallet location, wide-aisle pallet racking (forklift)0.5–0.9m²/location17 November 2026
Gross area per pallet location, narrow-aisle pallet racking0.25–0.4m²/location17 November 2026
Gross area per pallet location, automated high-bay warehouse0.1–0.2m²/location17 November 2026
Gross area per pallet location, mobile racking0.3–0.5m²/location17 November 2026
Gross area per bin location, shelving (manual)0.08–0.15m²/location17 November 2026
Gross area per bin location, automated miniload0.02–0.05m²/location17 November 2026
Gross area per bin location, shuttle system0.02–0.04m²/location17 November 2026
Gross area per bin location, AutoStore0.02–0.04m²/location17 November 2026
Supplementary area allowance (inbound, outbound, picking, traffic routes)40–80% of storage area17 November 2026
Technology recommendation: location count per technology (from / to) · Block stacking (floor storage)1–10,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Wide-aisle pallet racking1–5,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Narrow-aisle pallet racking1,000–15,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Automated high-bay warehouse5,000–100,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Mobile racking200–5,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Shelving (manual)1–10,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Automated miniload5,000–200,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · Shuttle system10,000–300,000locations17 November 2026
Technology recommendation: location count per technology (from / to) · AutoStore5,000–500,000locations17 November 2026
Technology recommendation: throughput per technology (from / to) · Block stacking (floor storage)0–150storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Wide-aisle pallet racking0–200storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Narrow-aisle pallet racking0–150storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Automated high-bay warehouse50–1,500storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Mobile racking0–60storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Shelving (manual)0–300storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Automated miniload100–2,000storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · Shuttle system300–10,000storage and retrieval moves per hour17 November 2026
Technology recommendation: throughput per technology (from / to) · AutoStore100–3,000storage and retrieval moves per hour17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Block stacking (floor storage)4–8m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Wide-aisle pallet racking6–10m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Narrow-aisle pallet racking8–14m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Automated high-bay warehouse12–45m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Mobile racking6–10m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Shelving (manual)2.5–6m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Automated miniload6–20m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · Shuttle system6–20m17 November 2026
Technology recommendation: usable hall height per technology (from / to) · AutoStore4–8m17 November 2026
Range width of the output (± around the default when a value has only a default)15%17 November 2026
Operating hours per day (converts the daily throughput to the hourly thresholds)16hours per day17 November 2026

Experience values of Bross Consulting, as of 17 November 2026. The range is a first order of magnitude and does not replace planning.

Contact

From the range to reliable planning

A first conversation is enough to clarify the starting point, the data basis and the next sensible step.